Manual APC Back-UPS 800. View the APC Back-UPS 800 manual for free or ask your question to other APC Back-UPS 800 owners. Back-UPS®Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct. (Back-UPS RS 1500 only). The Back-UPS will display these fault messages. For faults FOI and F02, contact APC Technical Support. £SEE L.U.MANUAL FOl On-Battery Overload Turn the Back-UPS off. Disconnect non-essential.
Page 2: Contact information, Limited warranty, Transfer voltage and sensitivity adjustment
SPECIFICATIONS
Item
Specification
On-line Input Voltage Range
(default settings)
83 - 147 Vac (RS model)
83 - 139 Vac (XS model)
Automatic Voltage Regulation (AVR)
+12% (XS model) +12% (RS model)
On-line Frequency Range
47 - 63 Hz (autosensing)
On-battery Waveshape
Stepped Sine Wave
Maximum Load
1000 VA - 600 W 1500 VA - 865 W
Typical Recharge Time
8 Hours
Operating Temperature
32
o
to 104
o
F
0
o
to 40
o
C
Storage Temperature
23
o
to 113
o
F
-5
o
to 45
o
C
Operating / Storage Relative Humidity
0 to 95% non-condensing
Size (H x W x D)
14.6 x 3.4 x 13.1 inch
37.1 x 8.6 x 33.3 cm
Weight
1000 VA 22 lbs (10 kg)
1500 VA 25 lbs (11 kg)
Shipping Weight
1000 VA 23 lbs (11 kg)
1500 VA 26 lbs (12 kg)
EMI Classification
FCC / DOC Class B Certified
On Battery Run-Time
See http://www.apc.com/product
TROUBLESHOOTING
Problem
Possible Cause
Corrective Action
Back-UPS will not switch on.
Back-UPS not connected to AC power source.
Ensure the Back-UPS is securely connected to an AC outlet.
Back-UPS circuit breaker 'tripped'.
Disconnect non-essential equipment from the Back-UPS. Reset
(push in) the rear panel circuit breaker. Switch on the Back-UPS
and plug in devices one at a time. If the circuit breaker trips
again, disconnect the device that caused the breaker to trip.
Utility input voltage quality is out of range.
Consider adjusting the transfer voltage and sensitivity. See
Transfer Voltage and Sensitivity Adjustment.
Back-UPS does not power
essential equipment during an
outage.
Equipment plugged into a Surge Only outlet.
Unplug device from 'Surge Only' outlet and move to a 'Battery
Backup' outlet.
Back-UPS operates on battery
although utility power exists.
Back-UPS circuit breaker 'tripped'.
Disconnect non-essential equipment from the Back-UPS. Reset
(push in) the rear panel circuit breaker. Switch the Back-UPS on
and plug equipment in one-at-a-time. If the circuit breaker trips
again, disconnect the device that caused the breaker to trip.
Utility input voltage quality is out of range.
Consider adjusting the transfer voltage and sensitivity. See
Transfer Voltage and Sensitivity Adjustment.
Back-UPS does not provide
expected backup time.
Back-UPS is heavily loaded.
Unplug non-essential equipment (printers, scanners, etc) from
the Battery Backup outlets and plug into 'Surge Only' outlets.
Back-UPS battery cartridge is discharged due to
recent power outage and has not had time to
recharge.
Charge the battery cartridge for 8 hours. Back-UPS runtime is
reduced until the battery cartridge is fully charged.
Battery has reached the end of its life.
Replace battery cartridge (see Order Replacement Battery
Cartridge).
Red Replace Battery indicator is
flashing. Green On Line indicator
is on.
Internal battery cartridge is not connected.
Connect battery cartridge (see Connect Battery Cartridge).
Red Replace Battery indicator is
on.
Battery has reached the end of its life.
Replace the battery cartridge (see OrderReplacement Battery
Cartridge).
Red Overload indicator is on or
flashing.
Connected equipment is drawing more power than
the Back-UPS can provide.
Move one or more equipment power plugs from Battery Backup
outlets to Surge Only outlets.
Green On Line indicator is on and
all other front panel indicators are
flashing.
Internal UPS fault.
Contact APC Technical Support (see Contact Information).
Battery
Cartridge
REPLACE BATTERY CARTRIDGE
ORDER REPLACEMENT BATTERY CARTRIDGE
The battery cartridge typically lasts 3-6 years, shorter if subjected to frequent outages or elevated temperatures. Order part number RBC33.
Please recycle spent battery cartridges.
990-2163A Copyright © 2007 American Power Conversion All rights reserved.
APC and Back-UPS are registered trademarks of American Power Conversion.
All other trademarks are the property of their respective owners.
SERVICE
If the Back-UPS arrived damaged, notify the carrier.
If the Back-UPS requires service, do not return it to the dealer. The following
steps should be taken:
1.
Consult the Troubleshooting section to eliminate common problems.
2.
If the problem persists, go to http://www.apc.com/support/.
3.
If the problem still persists, contact APC Technical Support.
• Have the Back-UPS model number, serial number and date of purchase
available. Be prepared to troubleshoot the problem with an APC Technical
Support representative. If this is not successful, APC will issue a Return
Merchandise Authorization (RMA) number and a shipping address. Lg 55 b7 web os user manual.
CONTACT INFORMATION
Technical Support
http://www.apc.com/support
Internet
http://www.apc.com
USA / Canada
1.800.800.4272
Mexico
292.0253 / 292.0255
Brazil
0800.12.72.1
Worldwide
+1.401.789.5735
LIMITED WARRANTY
The standard warranty is two (2) years from the date of purchase. APC's standard
procedure is to replace the original unit with a factory reconditioned unit. Customers
who must have the original unit back due to the assignment of asset tags and set
depreciation schedules must declare such a need at first contact with an APC Technical
Support representative. APC will ship the replacement unit once the defective unit has
been received by the repair department, or cross-ship upon the receipt of a valid credit
card number. The customer pays for shipping the unit to APC. APC pays ground
freight transportation costs to ship the replacement unit to the customer.
In situations where the Back-UPS or connected equipment appears too sensitive to
input voltage, it may be necessary to adjust the transfer voltage. This is a simple task
requiring use of the front panel pushbutton. To adjust the transfer voltage, proceed as
follows:
1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a
Standby Mode (no indicators lit).
2. Press the front panel pushbutton fully inward for 10 seconds. All indicators on the
Back-UPS will flash to acknowledge going into Programming Mode.
3. The Back-UPS will then indicate its current Sensitivity Setting, as shown in the
following table.
4. To select the Low Sensitivity setting, press the pushbutton until the yellow
indicator is flashing.
5. To select the Medium Sensitivity setting, press the pushbutton until the yellow
and red indicators (second and third from the top) are flashing.
6. To select the High Sensitivity setting, press the pushbutton until yellow and both
red indicators (bottom three) are flashing.
Apc Back Ups Rs 1300 User Manual Online
7. To exit without changing the Sensitivity Setting, press the pushbutton until the
green indicator is flashing.
8. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds,
the Back-UPS will exit Programming Mode; all indicators will extinguish.
Indicators
Flashing
Sensitivity
Setting
Input Voltage
Range
(for utility
operation)
RS Models
Input Voltage
Range
(for utility
operation)
XS Models
Use When
1
(yellow)
Low
78 - 150 Vac
78 - 142 Vac
Input voltage is
extremely low or high.
Not recommended for
computer loads.
2
(yellow,
and red)
Medium
(factory
default)
83 - 147 Vac
83 - 139 Vac
Back-UPS frequently
goes On Battery.
3
(yellow,
red, and
red)
High
default)
83 - 147 Vac
83 - 139 Vac
Back-UPS frequently
goes On Battery.
3
(yellow,
red, and
red)
High
88 - 144 Vac
Samsung galaxy s4 user manual video. 88 - 136 Vac
Connected equipment is
sensitive to voltage
fluctuations .
TRANSFER VOLTAGE AND SENSITIVITY
ADJUSTMENT
Notice: This device complies with part 68 and 15 of the FCC rules.Operation is subject
to the following two conditions: (1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may
cause undesired operation.
On the bottom of this equipment is a label that contains, among other information, the
FCC registration number and ringer equivalence number (REN) for this equipment. If
requested, this information must be provided to the telephone company.
This manual is encoded in PDF file format
The PDF (Portable Document Format) was created in the early 1990's as a brand new way for computer users to share documents between each other, especially if one person has a PC and the other a Mac. The shared PDF will display exactly the same on both computers.
PDF was created by Adobe and is no maintained by the International Organisation for Standardisation (ISO). It is a very interactive format and can contain buttons, links, audio, video, form fields, business logic and even electronic signatures. It can capture fonts, images as well as document texts and can also format documents from many different programs.
Most PDF viewers or the software used to view the PDF is provided free of charge. There are many options available including Scribus, pdfTex, Adobe InDesign, Adobe Illustrator as well as Google Docs. The most popular however is Acrobat Reader DC.
Apc Ups Pro 1300 Manual
Why we provide APC Power Supply manuals in PDF?:
- · PDF's are incredibly convenient and are easy to open and read by everyone, regardless of whether they have a PC or Mac.
- · A PDF can be compressed into a file size that is easy to email while still maintaining the quality of the images.
- · A PDF file can be made incredibly secure as you can set up passwords, digital signatures and even watermarks.
- · A PDF allows you input many different types of content including images, animations, 3D models, hyperlinks and buttons.
PDF's do have their drawbacks such as:
- · PDF's can often be difficult to edit or to extract information from as it's original intention was to make the exchange of documents easier.
- · There are different types of PDF's, especially when searching or extracting information.
Apc Back Ups 1300 Manual
If you have a document that you would like to convert into a PDF, there are many sites online that will do the conversion for you for free and very quickly. The same is true if you are looking to convert from PDF format into a different format. This is often a much easier way to edit a PDF.